Electrical Design
Electrical design specifies how power is distributed safely and reliably through a building, from the incoming service to lighting, emergency systems, and vehicle charging. FarHeater Engineering designs low-voltage distribution, lightning protection, emergency power, and EV charging stations.
Electrical design specifies how power is distributed safely and reliably through a building, from the incoming service to lighting, emergency systems, and vehicle charging. FarHeater Engineering designs low-voltage distribution, lightning protection, emergency power, and EV charging stations.
Lightning Protection Systems for High-Risk Facilities — we design and implement lightning protection systems that safeguard critical facilities from electrical surges and minimize the risk of damage to infrastructure and equipment. Low Voltage Distribution Systems for Reliable Power — our low-voltage distribution systems ensure the safe and efficient delivery of power to all parts of a facility, enhancing reliability and performance. Electric Vehicle Charging Stations (EVCS) Design — with the growing demand for electric vehicles, we provide custom designs for EV charging stations in residential, commercial, and public spaces, supporting a sustainable future. Emergency Power Systems for Critical Facilities — we specialize in designing emergency power systems, including standby generators and UPS systems, to ensure uninterrupted operations for essential services during power outages.

Designing to the Ontario Electrical Safety Code
Electrical work in Ontario is governed by the Ontario Electrical Safety Code, the provincial adoption of CSA C22.1, and is administered by the Electrical Safety Authority rather than the municipal building department. That distinction matters in practice: electrical drawings follow a separate review and inspection path from the architectural and mechanical permit set, on a different timeline. We design to the OESC and the Ontario Building Code where life-safety provisions apply, and our drawings are sealed by a licensed Professional Engineer.
From the utility service to the final circuit
A complete electrical design starts with the connected and demand load calculation, which determines the service size and the conversation with the local distributor — Toronto Hydro, Alectra or whichever utility serves the site. From there it works through transformers, main distribution, panelboards, feeders and branch circuits, with short circuit and protective device coordination studies where the installation warrants them. Getting the service size right early matters more than almost anything else in the package, because a utility upgrade discovered late can add months to a programme.
EV charging and electrical capacity
Electric vehicle charging has moved from an optional extra to a requirement on most new development, and in the City of Toronto the Toronto Green Standard sets provision levels for new construction. The engineering question is rarely the chargers themselves but the capacity behind them: whether the service and distribution can carry the load, and whether load management can defer an expensive upgrade. In existing buildings that assessment is the whole job, and we carry it out before anyone commits to a charger count.
Lighting, emergency systems and protection
The package also covers interior and exterior lighting with the controls the energy code requires, emergency lighting and exit signage to the Ontario Building Code, power and monitoring for fire alarm and life-safety equipment, and lightning protection where exposure or occupancy justifies it. Where photometric calculations are needed for Site Plan Approval, we produce those as part of the same design rather than as a separate exercise.
Get a quote for Electrical Design
Tell us about the building, the scope and your timeline. An engineer will come back to you with next steps, usually within one business day.
Mon-Fri: 8:30 AM - 5:00 PM
Electrical Design — frequently asked
- Do you design EV charging station (EVCS) installations?
- Yes. We design EV charging for residential, commercial, and public parking, including the load calculations and distribution capacity the installation requires.
- What is a lightning protection system and does my building need one?
- It is a network of air terminals, conductors, and grounding that gives a lightning strike a safe path to earth. It is typically warranted for tall, exposed, or critical facilities.
- Can you design emergency and standby power systems?
- Yes — standby generators, UPS systems, and automatic transfer switches, designed so essential loads keep running through a utility outage.
- Who reviews electrical drawings in Ontario?
- The Electrical Safety Authority, not the municipal building department. Electrical design follows its own review and inspection path, which runs on a different timeline from the building permit, so it is worth starting early.
- How do I know if my electrical service is large enough?
- It comes from a demand load calculation against the actual and proposed loads, not a rule of thumb. We carry that out early, because if a utility service upgrade is required it is usually the longest lead item on the project.
- Can you assess whether our building can support EV chargers?
- Yes. That assessment — spare capacity, distribution, and whether load management can avoid a service upgrade — is typically the main piece of work, and it should precede any decision on how many chargers to install.
- Do you provide short circuit and coordination studies?
- Yes, where the installation warrants them. These confirm that protective devices are correctly rated and that they operate selectively, so a fault takes out the smallest possible part of the system.
Sectors we deliver this service in
Ready to engineer your next project?
Tell us about your building. We'll show you the most efficient, compliant and cost-effective path from concept to completion.