Emergency Diesel Generator Systems Design

Emergency power system design specifies the generators, UPS units, and transfer switches that keep a building's critical systems running through a utility outage. FarHeater Engineering designs and commissions these systems for facilities where downtime is not an option.

Emergency power system design specifies the generators, UPS units, and transfer switches that keep a building's critical systems running through a utility outage. FarHeater Engineering designs and commissions these systems for facilities where downtime is not an option.

Power resilience is essential for critical facilities, and our emergency diesel generator designs ensure uninterrupted operations during outages. We provide tailored solutions for standby generators, UPS systems, and automatic transfer switches to meet the unique requirements of each facility. From design to commissioning, we ensure seamless integration and reliable performance, protecting vital equipment and operations when it matters most.

Emergency Diesel Generator Systems Design by FarHeater Engineering

Designing to CSA C282

Emergency electrical power for buildings in Ontario is governed by CSA C282, which sets out requirements for the generating set, its fuel supply, the transfer scheme and the testing regime that keeps it dependable. The Ontario Building Code determines which buildings need emergency power and which loads must be supported; CSA C282 governs how that system is built and maintained. Designing against both from the outset avoids the common outcome where a set is installed that meets the load but cannot satisfy the standard's fuel or testing provisions.

Sizing the set properly

Generator sizing is more subtle than totalling the connected load. Motor starting inrush, step loading sequences, and the non-linear loads presented by UPS systems and variable frequency drives all affect the set required, and getting them wrong shows up as voltage dip or frequency excursion when the system is finally tested. Oversizing is its own problem: a diesel running lightly loaded for long periods suffers wet stacking and unreliability. We model the load steps and size for the real duty rather than a worst-case sum.

Fuel, exhaust, ventilation and noise

The engineering around the set is usually what constrains the design. Fuel storage falls under TSSA requirements and the standard dictates the run time the building must sustain. The set needs combustion and cooling air, an exhaust route with appropriate separation, and acoustic treatment that satisfies the municipality's noise provisions — which in a dense urban site is frequently the governing constraint. Location, fire separation and weather protection are resolved alongside the architect rather than after the fact.

Transfer schemes and critical branches

An automatic transfer switch senses utility failure and transfers load to the generator, and the choice between open and closed transition affects whether sensitive equipment sees an interruption during the return to utility power. Which loads sit on the emergency branch, which on standby, and which are allowed to drop is a design decision with cost implications, and in healthcare it is tightly prescribed. We set that hierarchy with the client early, because retrofitting it later means re-running feeders.

Get a Quote

Get a quote for Emergency Diesel Generator Systems Design

Tell us about the building, the scope and your timeline. An engineer will come back to you with next steps, usually within one business day.

Mon-Fri: 8:30 AM - 5:00 PM

We typically respond within one business day.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Common Questions

Emergency Diesel Generator Systems Design — frequently asked

How do I size an emergency generator for my building?
By identifying which loads must stay energised — life safety, elevators, critical equipment — then calculating their combined demand plus starting inrush. We carry out that analysis as part of the design.
What is an automatic transfer switch (ATS)?
An ATS senses the loss of utility power and automatically switches the building's essential loads over to generator supply, then transfers back once utility power is stable.
Which buildings are required to have emergency power?
Requirements depend on occupancy and code, but hospitals, long-term care, high-rise residential, and many institutional buildings must maintain power to life safety systems.
Which standard governs emergency generators in Ontario?
CSA C282 covers emergency electrical power supply for buildings, including the set, fuel supply, transfer and testing. The Ontario Building Code determines which buildings require emergency power and which loads it must serve.
Can a generator be oversized?
Yes, and it is a common and costly mistake. A diesel set running lightly loaded for extended periods suffers wet stacking, which reduces reliability. Sizing should follow the actual load steps rather than a conservative total.
How long does the generator need to run on stored fuel?
That depends on the building's occupancy and the governing requirements, and it drives tank sizing and location. Fuel storage is also subject to TSSA requirements, so it is confirmed at design stage rather than assumed.
Is generator noise a problem in urban sites?
Frequently, yes. Municipal noise provisions often govern the installation on dense sites, and acoustic attenuation, exhaust routing and enclosure selection have to be designed around them rather than added later.