Fire Alarm Systems Design
Fire alarm system design specifies the detectors, control panels, and notification devices that warn occupants of a fire and trigger a building's safety response. FarHeater Engineering designs these systems for healthcare, hospitality, commercial, and residential buildings.
Fire alarm system design specifies the detectors, control panels, and notification devices that warn occupants of a fire and trigger a building's safety response. FarHeater Engineering designs these systems for healthcare, hospitality, commercial, and residential buildings.
A robust fire alarm system is essential for any building's safety. At FarHeater Engineering Inc., we design comprehensive fire alarm systems, specifying smoke detectors, heat sensors, control panels, and emergency notification devices. Our systems are customized for various facility types, including hospitals, hotels, commercial offices, and residential buildings. From initial design through verification, we ensure every component works together to provide reliable, life-saving functionality in an emergency.

Fire alarm design to CAN/ULC and the Ontario Building Code
Fire alarm systems in Ontario are designed to CAN/ULC-S524, the standard for installation of fire alarm systems, within the framework the Ontario Building Code sets for the building's occupancy and size. The Code determines whether a system is required at all, whether it must be single or two stage, and what detection coverage applies. We prepare sealed drawings showing device locations, circuiting, annunciation and the sequence of operations, and we carry them through the authority's review to approval.
Integration with the rest of the building
A fire alarm system is rarely standalone. It recalls elevators to a designated floor, shuts down or repositions air handling equipment to limit smoke spread, releases magnetic door hold-opens, unlocks access-controlled egress doors and, in some buildings, initiates smoke control. Each of those interfaces has to be specified and coordinated with the mechanical, electrical and security designs, and written into the sequence of operations. Because FarHeater designs the mechanical and electrical systems as well, that coordination happens within one team rather than across three.
Single-stage, two-stage and voice communication
A single-stage system sounds a general alarm everywhere at once and suits most smaller buildings. A two-stage system sounds an alert signal first, giving staff an interval to investigate before general evacuation, and is common in hospitals, hotels and larger assembly buildings. High-rise buildings generally require a voice communication system so that occupants can be given phased instructions, along with firefighter telephone provisions. Which applies is driven by the Code and the building's occupancy, and it shapes panel selection and circuiting from the start.
Verification, retrofits and existing buildings
Once installed, a fire alarm system must be verified to CAN/ULC-S537 before the building is occupied, and inspected and tested thereafter to CAN/ULC-S536. We design with that process in mind so verification does not surface problems late. Retrofits and panel replacements in occupied buildings are a regular part of our work — hotels, hospitals and apartment buildings cannot simply close — so these are planned in phases that maintain continuous protection while the changeover proceeds.
Get a quote for Fire Alarm Systems Design
Tell us about the building, the scope and your timeline. An engineer will come back to you with next steps, usually within one business day.
Mon-Fri: 8:30 AM - 5:00 PM
Fire Alarm Systems Design — frequently asked
- What components make up a fire alarm system?
- Smoke and heat detectors, manual pull stations, a control panel, notification appliances such as horns and strobes, and the interconnections to elevators, HVAC, and door hardware.
- Which standards do your fire alarm designs follow?
- CAN/ULC standards, the Ontario Building Code, and the requirements of the local authority having jurisdiction, coordinated with the building's fire protection strategy.
- Do you design fire alarms for existing buildings and retrofits?
- Yes. Retrofits and upgrades to occupied buildings are a regular part of our work, including phased designs that keep the building in service.
- What is the difference between a single-stage and a two-stage fire alarm system?
- A single-stage system sounds a general alarm throughout the building immediately. A two-stage system sounds an alert signal first, allowing trained staff a defined interval to investigate before general evacuation. Two-stage systems are common in hospitals, hotels and larger assembly buildings, and which one applies is determined by the Ontario Building Code.
- Does a new fire alarm system need to be verified?
- Yes. Fire alarm systems must be verified to CAN/ULC-S537 before the building is occupied, and inspected and tested afterwards to CAN/ULC-S536. We design with verification in mind so that issues are not discovered at the end of the project.
- Do you install fire alarm systems?
- No. FarHeater is a consulting engineering firm. We design the system, produce sealed drawings for permit and carry out field review during construction. Installation is performed by a licensed contractor, and we review their work against the design.
- Can you coordinate the fire alarm with elevators and HVAC?
- Yes, and it is essential. Elevator recall, air handling shutdown, door hold-open release and access control interfaces all have to be written into the sequence of operations. Because we design the mechanical and electrical systems too, that coordination happens inside one team.